Original Articles Vol. 3 No. 3 (2026): Bioscience Insights Published 2026-11-25

DATA LEAKAGE AND REPORTED ACCURACY OF DEEP LEARNING FOR INTERSTITIAL LUNG DISEASE ON COMPUTED TOMOGRAPHY: A METHODOLOGICAL SYSTEMATIC REVIEW

Authors

  • Adyan Ahmad Department of Computer Science, Bacha Khan University Charsadda, Charsadda, Pakistan Pakistan Author
  • Adyan Ahmad Department of Computer Science, Bacha Khan University Charsadda, Charsadda, Pakistan Pakistan Author
  • Arsalan Haleem Department of Electronic Engineering Government Post Graduate Jehanzeb College, University of Swat, Mingora, Pakistan Pakistan Author
  • Asad Khan Department of Computer Science, Bacha Khan University Charsadda, Charsadda, Pakistan Pakistan Author
  • Dr. Qurratulain Aamir OTHM Diploma in Health and Social Care Management, UK. Pakistan Author
  • Ahmad Saeed Department of Computer Science, Bacha Khan University Charsadda, Charsadda, Pakistan Pakistan Author
0 views 0 downloads

Abstract

Deep learning (DL) classifiers for interstitial lung disease (ILD) on computed tomography (CT) often report accuracies above 95%, but whether their test data were independent of model development is unclear. This methodological systematic review searched six sources and citation links to 28 October 2026 for studies using DL to classify ILD diagnoses or patterns on CT. Partitioning was graded from quoted source text and tests by whether they used independent patients. Of 35 included studies, 24 (69%) had a high risk of bias, 12 documented sub-patient partitioning and five were suspected of it. Median accuracy was 95.0% with documented sub-patient and 82.9% with patient-level partitioning (p = 0.018), and all six accuracies of 98% or more came from studies without patient-level partitioning. These were all pattern classifiers evaluated on patches, slices or images, so partitioning could not be separated from task and prediction unit. Eleven studies tested on independent patients, and performance fell in five of the seven with an internal comparison. On the Geneva database, accuracy rose from 85.5% to 99.8% while evaluation remained largely patch-level. One study released code; the median reproducibility score was 1 of 6. Patient-level partitioning and testing on independent patients should be minimum standards.

Keywords

  • Lung Diseases, Interstitial; Deep Learning; Tomography, X-Ray Computed; Systematic Review; Data leakage

Views & Downloads Statistics (Last 12 Months)

Monthly performance and trends of article views and downloads

Views (12 months)0
Downloads (12 months)0
Article Views PDF Downloads